Monophased or three-phased: what power supply for its professional equipment?
230 V or 400 V, power, dedicated socket, subscription: understand the power supply before buying an oven, a fryer or a professional cold group.
By the team DIYA PRO, Toulon · updated on 14 novembre 2026
In brief
The single phase (230 V) is suitable for low-power devices: up to 3,5 kW on a 16 A socket, a little more on a dedicated circuit in 20 or 32 A. Beyond, or for several large devices, it takes three phases (400 V). The voltage is indicated on each product sheet: check it before you buy.
How do I know what I have?
Ouvrez votre tableau électrique : un disjoncteur de branchement à 4 pôles (3 phases et le neutre) signale du triphasé. Your electricity contract also indicates the type of connection and the power subscribed in kVA. In case of doubt, an electrician checks it in a few minutes.
Orders of magnitude in 230 V
The available power depends on the size of the circuit:
- Classic 16 A socket: approx. 3,5 kW maximum (small fryer, crepe maker, plate, panini machine).
- 20 A dedicated circuit: about 4,5 kW.
- Dedicated circuit 32 A: about 7 kW (furnace or fryer more powerful).
When the three phases become indispensable
Twin-chamber pizza ovens, large floor-standing fryers, combi ovens, some dough mixers and cold room units often require 400 V. Three-phase power distributes the load across three phases and is standard in professional kitchens.
Switching from single phase to three phase is asking the electricity supplier (intervention of the system operator); the cost and time vary depending on the housing or the premises.
Before ordering
Three reflexes avoid bad surprises:
- Read the voltage and power on the product plug (230 V or 400 V, in kW).
- Add the power of all devices that will spin at the same time and compare to your subscription.
- Have the connection carried out by a qualified electrician, especially for the 400 V.
See the material in the catalogue
Start price calculated live from the catalogue DIYA PRO.
Frequently asked questions
Can we connect a 400 V device to 230 V?
No. A 400 V three-phase device does not work on a single-phase installation, and an inappropriate connection can damage it.
What power on a 16A socket?
About 3,5 kW in 230 V. For more, it requires a dedicated circuit of higher calibre or three phases.
Can an individual use professional equipment?
Yes if the voltage and power match its installation. Many housing units are single-phase: 400 V devices are unusable without changing their connection.
Do you have any doubts about your choice?
Our advisors in Toulon check with you the tension, dimensions and budget before purchasing.